Limit search to items available for checkout
E-BOOK
Title Pipelines 2014 : from underground to the forefront of innovation and sustainability : proceedings of the Pipelines 2014 Conference, August 3-6, 2014, Portland, Oregon / sponsored by the Pipeline Division of the American Society of Civil Engineers ; edited by Shah Rahman, David McPherson.
Imprint Reston, Virginia : American Society of Civil Engineers, [2014]
©2014

Copies/Volumes

LOCATION CALL # STATUS
 Internet  Electronic Book    AVAILABLE
Description 1 online resource (2281 pages) : color illustrations
Bibliog. Includes bibliographical references.
Note Available only to authorized UTEP users.
Online resource; title from PDF title page (viewed October 1, 2014).
Subject Pipelines -- Congresses.
Genre Conference papers and proceedings.
Contents Development of a Risk Assessment Tool for Managing PCCP Assets with Broken Wires -- Ocean Wastewater Outfall Infrastructure Needs Love Too : Strategies to Perform a Successful Assessment Program -- Optimizing Small Water Main Renewal Using Nondestructive Examinations -- Fort Worth Interceptor Condition Assessment Leads to Improved Asset Management and Long-Term Sustainability -- Starting a Condition Assessment Program for PCCP in Tampa Bay Water's Wholesale System -- Overview of the Explosion of a 30-In. Steel Natural Gas Pipeline in San Bruno, California -- A Tale of Two Utilities : How Portland Water (Oregon) and WaterOne (Kansas) Justify and Apply Condition Assessment for Pipe Risk Management -- Analysis of a 60-In. PCCP that Failed without Warning from Acoustic Fiber Optic System -- Digging in the Dark : Making Asset Management Decisions in the Age of Imperfect Information -- Renewal of Denver Water's North System : Conduits 16 and 22 Assessment and Alternatives Analysis -- Concrete Bar-Wrapped Cylinder Pipe (C303) Condition Assessment and Verification Increases Reliability of TRA's Water Delivery.
Problems beneath the Tracks : Condition Assessment of 1940s Vintage Cast Iron Water Mains underneath the Alaska Railroad -- Tucson Water's Homegrown Condition Assessment of PCCP -- Hands-On Experience with the Broadband Electromagnetic Tool in the Trench -- Developing a Workable Condition Assessment Program When Your Budget Is Extremely Limited -- Detecting the Effects of Inadequate PCCP Bedding -- What In-Line Technologies Work Best for Condition Assessment of Pipelines and Why -- Corrosion Control Strategies to Protect Linear Assets : Dundas Street Sanitary Sewer and Forcemain Project, Oakville in the Region of Halton, Ontario, Canada -- Field Trial : Inspection of Cement Mortar-Lined Ductile Iron Pipe -- Concrete Bar-Wrapped Cylinder Pipe (C303) Condition Assessment Increases the Reliability of the City of Calgary's Water Infrastructure -- Risk-Based Condition Assessment and Rehabilitation Planning in Colorado Springs -- Initial Condition Assessment of the 3,000 mm (120 in.) Diameter Primary Trunk Interceptor for the Region of York -- Advanced Acoustic Monitoring for PCCP -- Rainfall Requirements for Wet Weather Sewer Evaluation -- Predicting the Remaining Life of Asbestos Cement Pipe with Acoustic Wall Thickness Testing -- Test Protocol for Evaluating Grout Materials to Repair Water Leaks in Concrete Pipes -- Large-Diameter Pipeline Construction through an Urban Corridor : The Westside Header Relocation, Phase 2 Project.
Design, Pipe Material Selection, and Manufacture for the Lake Texoma Outfall Raw Water Pipeline : Genesis of a Fast-Paced Large-Diameter Project -- Comparing Different Embedment Options for an Open-Cut Pipeline Project -- Study of the Consolidation Process of Drilling Fluid in Annular Space after HDD Construction -- PCCP Rehabilitation with Fiber-Reinforced Polymer Composite : Confirming Installation Conditions -- Complex Infrastructure Projects Made Simple -- Conceptual Cost-Estimating Model for Water and Sewer Projects -- Construction and Commissioning of a Complex Wet Weather Storage System in Baton Rouge -- Alternative Project Delivery : iPod or New Coke? -- Importance of Haunching -- Industry Perceptions of Trenchless Pipelines Project Performance when Using Alternative Delivery Systems -- It's Not a Pipe Dream Crossing the St. Johns River with One of the Southeast's Largest Directional Drilling Projects -- HDD Installation Practices for Buried Pipeline Energy Infrastructure in China -- Unique Design, Manufacturing, and Installation Challenges for the CW System at the Ninemile Unit 6 CCGT Project -- Waterline Replacement Project in Ogden Canyon, UT, Presents Unique Construction Challenges -- McCook 33 ft Diameter Main Line Tunnel Liner for the Chicago TARP -- Field Measurements of Pipe Ramming-Induced Ground Vibrations.
Innovative Joint Designed for an 84 in. Raw Water Transmission Main Tunnel Carrier Pipe -- Fast-Tracked HDD in Biscayne Bay for Emergency Bridge Replacement -- Testing the Quality of Pipeline Joint Protection Installation -- City of San José Uses Creativity to Keep a Critical Link from Becoming a "Missing Link" -- Mill Wood's Double Barrel Replacement Tunnels -- Southwest Metropolitan Water and Sanitation District : Implementing a Phased Rehabilitation of an Entire Interceptor System -- Conquering Construction Challenges during PCCP Rehabilitation -- Models to Predict the Rate of Penetration of Insulator-Coated Pipe into Very Soft Clays Simulating Deepwater Subsea Conditions -- Reducing Risk Caused by Existing Utilities during Construction of New Pipelines -- Design of Supplementary Intake from Lake Sakakawea for the Southwest Pipeline Project -- Grit Transport in a Force Main with Adverse Slopes -- Useful Tips and Tools for Design of Ductile Iron and PVC Pipelines -- Full-Scale Testing of an EPS Geofoam Cover System to Protect Pipelines at Locations of Lateral Soil Displacement -- Saturated Sand Moduli Using CPT in Pipe Design -- Geotechnical Investigation and Evaluation Methods for the Design of Water Pipelines in Soil -- Regional Carrizo Program : Planning, Design, and Construction of a Fast-Track Urban Pipeline -- Additional Design Considerations for Special Applications of Steel Pipe.
"I'll Take One of Everything" : Utilizing a Menu Approach to Tunnel Design -- Early Selection of Check Valve Type Considering the "Slam" Phenomenon -- Settlement Analysis of Box Jacking Projects -- Magical Charts for Effective E' : Removing the Smoke and Mirrors -- Large-Diameter Steel Water Pipe : Comparing Classic and Recent Design Procedures for External Earth Loads -- Which Method to Use when Estimating Maxi-HDD Installation Loads : ASTM F 1962 or the PRCI Method? -- Hydraulic Transient Analysis of the Tarrant Regional Water District and the City of Dallas's Integrated Pipeline System -- Fast-Track Design-Build of 93 km (58 mi) Water Transmission Pipeline in West Texas -- Innovative Directional Microtunnel Garners Success for Crucial Trenchless Crossing -- Fundamentals of a New Manual of Practice for the Design of Flexible Liners for Pipes Operating in Gravity Flow Applications -- Can Users Benefit from Pipe Standards that Allow Less Conservative Pressure Classifications? -- 16 mi Water Transmission Main Utilizes Multiple Materials and Methods to Overcome Alignment Challenges in the Florida Panhandle -- Vacuum System Reduces Pump Station Power Consumption -- How to Successfully Plan and Design a Major Pipeline Replacement Project in a Congested Urban Setting -- A Nonoscillatory Shock Capturing-Based Numerical Model for Calculating Highly Transient Mixed Flow in Pipelines -- Design of Utility Pipelines through an Active, Urban Landslide : The City of Astoria's 11th Street Combined Sewer Overflow Separation Project -- Welding Details for Welded Steel Wye Branches -- Babe Ruth Drank Water from that Pipe? Upgrading a Century-Old Infrastructure in an Urban Environment.
San Diego County Water Authority Aqueduct Protection Program since 1992 : Evolution in Design and Construction of Steel Cylinder Relining of PCCP -- Numerical Analysis of Submerged Soil Behavior in Pipeline Installations Crossing Rivers -- Construction of a Large-Diameter Pipeline in Soft Soils between Two Reservoirs Using Alternative Project Delivery Method -- Cure Behavior of Epoxies Used for CFRP Repair of Pipelines -- Experimental Basis of CFRP Renewal of PCCP -- CFRP Renewal of PCCP : An Overview -- Design Challenges and Solutions to a River Water Transmission System -- Interconnection of Large-Diameter Transmission Pipelines -- Challenges Faced in the Design of Large-Diameter Forcemain : Dundalk Pumping Station Forcemain Replacement, City of Baltimore, Maryland -- A Quasi-Two-Phase Flow Model for Calculating Filling in Pipelines -- The TRWD 108 in. Line J : Lessons Learned from the IPL Prototype Project -- Mary Rhodes Phase 2 : Arming the Texas Coastal Bend against Drought -- Seismic Design of Buried Steel Water Pipelines -- Something Borrowed, Something New : Whites Branch Alternate Discharge Pump Station and Pipeline -- How to Properly Specify Welding Requirements : The Role of the Pipe Designer -- Centrifuge Model Test for Buried Inner Rehabilitated Pipes Affected by Aging Pipes with Different Damage Levels -- Optimization Technique for Design of Gravity Sewers and Related Aspects.
Discharge Pipes for a 875,000 gpm Pump Station -- Design of a Large-Diameter Wastewater Line under the Confines of a Storm Channel, from a Designer's and an Owner's Perspective -- Value Engineering and Final Design of a Hydraulic Surge Control System for a Major Raw Water Supply System : The Southern Delivery System -- City of Port Angeles, WA : Large-Diameter Bundled Slipline for a CSO Diversion Project -- Tucson Water's Strengthening Approach to Address Thrust Restraint for PCCP -- Balch Consolidated Conduit Transient Condition -- Structural Analysis of Deeply Buried Flexible Pipe at Waste Disposal Sites.
Gillette Madison Pipeline Project : Providing a Sustainable and Reliable Water System for the Gillette Regional Area -- Large Water Distribution Pipeline Calls for Challenging Trenchless Installation in Lake Oswego, Oregon -- Safeguarding a Buried Pipeline in a Landslide Region -- Analysis of Water Distribution Buried Jointed Pipe Networks Subjected to Seismic Waves Considering the Nonlinear Behavior of Connections -- A Long-Term Commitment to Pipeline Infrastructure : Implementing, Funding, and Delivering the San Diego County Water Authority's Asset Management Program -- A Generic Continuous Technical Reporting System Using Open-Source Technology -- Large-Diameter Pipe Failures Bring More than 50 Years of Improvement -- Evaluating the Resiliency of the Water System in Charleston, South Carolina against Liquefaction Hazard through the Use of Seismic Hazard Maps -- Historic Civil War Era 48-in. Outfall Sewers Fully Renewed Using CIPP Technology in Hoboken, NJ -- Quantitative Approach to Select Energy Benchmarking Parameters for Drinking Water Utilities -- Two Early Christmas Breaks, but a Happy New Year Emergency Pipeline Project -- SWSP : 18 Years of Evolution of a Water Supply Pipeline Project -- Repair of In-Service HDPE Water Distribution Pipe.
A Better Tool to Perform Double Block and Bleed Tapping and Plugging to Isolate Sections of Pipe for Repair or Modification -- Managing a Troubling Asset : An Asset Management Approach to Emergency Repair -- Zinc Metallizing for External Corrosion Control of Ductile Iron Pipe -- Pull-Off Adhesion Test for Coatings on Large Pipes : Possible Variations in Failure Location and Mode -- Evaluation of the Structural Performance of Epoxy Linings for Manhole Rehabilitation Using Laboratory Testing and FEM Simulations -- WATERiD's Web-Based Geospatial Tool for Economic Analysis of Water Pipeline Inspection and Renewal -- Breaking the Asset Management Mold : Why a Statistical Approach May Make More Sense -- Rehabilitation of the Herridge 1,500 mm Transmission Feedermain with Carbon Fiber-Reinforced Polymer : A Canadian First -- Do Broken Prestressing Wire Wraps at the Joint Affect the Safe Operation of a Pipe? -- Investigation of Severe Water Hammer in a Large Pump Station : Case Study -- C-Factor Testing as a Condition Assessment Tool for Wastewater Force Mains -- Rehabilitation of the Second Lower Feeder -- Methods for Postconstruction Evaluation of Horizontal Directional Drilled Utilities -- A Cautionary Tale about Unextended Proprietary Restrained Joints for Ductile Iron Pipe.
Sliplining Replacement of Carbon Steel Piping at a Power Generation Facility During Planned Outages -- Service Life Extension Option for Large-Diameter Potable-Water Transmission Pipelines -- Rehabilitation of the Deacon Reservoir Cell 1 and 2 Interconnector Pipes by Sliplining Methods under Full Reservoir Head -- Water Management Planning Tool for the Southern Delivery System, Colorado Springs, CO -- Tell Me the Available Fire Flow for Every Pipe in the System : Integration of Model Calibration, Infrastructure Planning, and Operation -- Innovative Fiber Optic Sensors for Pipeline Corrosion Monitoring -- Tacoma's Pipeline Assessment Project : Replacing the Right Mains at the Right Time -- What to Do after a Failure of PCCP : Forensic Evaluation of Pipe Failure in Green Bay -- Natural Disaster Response and Recovery : Lessons Learned in Trout Canyon and Kyle Canyon, Nevada -- Inspection Technologies to Keep the Pipeline in Service -- Managing Atlanta's Water Transmission Main with Transient Analysis : How Making Fine Adjustments Extends Asset Life -- Modeling Spatial and Functional Interdependencies of Civil Infrastructure Networks -- Biodeterioration of Portland Cement Mortar Produced by Sulfur Oxidizing Bacteria -- Fifteen Years of Lessons Learned : Design and Construction of CFRP Liners for Large-Diameter Pipelines.
Tactical Asset Management Plans for Linear Assets -- Water Hammer Induced by a Line Break -- DC Water's Rapid Repair of a Waste Water Treatment Plant Piping System -- Case Study of More than 10 Years of Maintaining Adequate Cathodic Protection Levels on a Campus with Mixed-Use Product Pipelines -- Municipal Adventures : Averting Disaster during a Critical Transmission Main Repair and Maintaining Pipeline Infrastructure in the City of Atlanta -- Flange Joints : Avoiding Installation Pitfalls -- Revisiting the Topic of Liability for Damage Due to Water Main Breaks or Leaks -- Planning and Executing an Effective Water Distribution System Replacement Program in Baltimore, MD -- Analysis of Cement Mortar Lining in the Presence of Hydrodynamic Loading -- Testing and Analysis of No-Dig Structural Manhole Rehabilitation Materials -- Testing Wastewater Pipe Joints for Infiltration -- National Survey on the Trends in Small-Diameter Water Pipeline Failures -- Pipeline Fragility Assessment against Liquefaction-Induced Differential Settlement in the Cities of Alameda and Oakland, California -- Not in My Front Yard : Overcoming Urban Pipeline Challenges -- How to Select and Prioritize the Replacement of Water Mains : An Owner's Perspective -- Utilizing Info-Gap Decision Theory to Improve Pipeline Reliability : A Case Study -- Municipal Wastewater Asset Prioritization Using Hierarchical Decision Modeling -- Analysis of Horizontal Directional Drilling Construction Risks Using the Probability-Impact Model : A Contractor's Perspective.
Planning Support Services for San Francisco's Auxiliary Water Supply System (AWSS) -- Seismic Reliability of Seawater Intake Tunnels for San Francisco's Auxiliary Water Supply System (AWSS) -- Research Needs and Recommendations for Testing Thurst Restraint of Buried Pipelines -- Developing a Successful Wastewater Collection System Rehabilitation Program in Corpus Christi, Texas -- River Gone Wild : Protecting a Large-Diameter Transmission Main from the River, Dallas, Texas.
Soil Parameters for Assessing Axial and Transverse Behavior of Restrained Pipelines Part 1 : Axial Behavior -- Soil Parameters for Assessing Axial and Transverse Behavior of Restrained Pipelines Part 2 : Transverse Behavior -- Evaluating Use of Large-Diameter HDPE Pipe for Water Transmission Applications -- Combined Sewer System Capacity Risk Assessment and Mitigation -- Shocking News : Analyzing AC-Induced Potentials on Buried Pipelines -- Exposure : Polyurethane Coating Response to Cyclic Heat Load and Ultraviolet Impact in the Texas Environment -- Portland's Sewer Rehabilitation Program Development and Implementation -- Outside Influences on Large-Diameter Pipeline Route Selection Processes -- You CAN Have It Both Ways : Building a Water Transmission Line and Pump Station to Meet Today's and Tomorrow's Customer Needs, Upper Trinity Regional Water District and CH2M Hill -- Feasibility Study of the Replacement/Rehabilitation of a 72-in. Force Main -- High-Resolution Surface Geophysics to Guide Pipeline Construction Projects -- Alternative Identification Methodology Maximizes Flexibility in Selecting Preferred Alternative for the Arkansas Valley Conduit -- In the Trenches : Parallel Pipe Design -- Planning and Developing a New Multi-Agency Regional Water Supply System -- Risk Assessment Model for Pipe Rehabilitation and Replacement in a Water Distribution System -- Long-Term Weathering Effects on Aromatic Polyurethane-Coated Pipe -- No Easy Way : Challenges Faced in Designing a Large Sewer Interceptor in a River Corridor.
SSOs : Locking Up Repeat Offenders -- Subsurface Exploration Statistics : A Snapshot of Design Risk Evaluation -- Sustainability of Lower Energy Costs by Utilization of Proper Pipeline Materials -- Establishing Right of Way : Large-Diameter Pipelines in Urban Areas -- Utility Asset Management Programming : Performance, Sustainability, and Resilience Moving from Academia to Practice -- Navigating an Environmentally Sensitive Area : Planning through Construction of a 54 in. Transmission Main in Austin, Texas -- An Introduction to Environmental Value Engineering (EVE) and the EVE Assessment of Horizontal Directional Drilling (HDD) versus Open-Cut Construction -- Planning for Sustainable Growth in the Antelope Valley, California : 22.5 mi of Transmission Main and Counting -- Filbin Creek 54 in. Gravity Sewer : How to Build a New Gravity Sewer Interceptor beneath an Interstate, under Three Railroads, and through a Swamp for North Charleston Sewer District -- Environmental and Design Challenges for a 1,500 mm Diameter Steel Pipeline River Crossing -- Construction Dewatering Near Environmentally Sensitive Locations -- Seismic Behavior of Box-Shaped Culverts Buried in Cohesionless Soils.
Locating and Quantifying Infiltration within an Agency Operating under a U.S. EPA Consent Decree -- The City of Portland's Search for Environmentally Preferable Pipe Materials -- Casselberry Asbestos Cement Pipe Bursting Project : Moving Forward by Leaving It Behind -- Understanding and Using AWWA Standards and Manuals -- Analyzing Transient Behavior and Cost Effectiveness of a TSE Transmission Line Considering Different Pipeline Materials -- The Oregon Resilience Plan for Water and Wastewater Systems -- Current Proposed Changes to AWWA M11 Steel Pipe : A Guide For Design and Installation -- Balancing Innovation with Historical Practices in Standards Development -- A Pipeline Relocation Win-Win -- Envision : A Measure of Infrastructure Sustainability -- Life-Cycle Procurement of Pumping Equipment for a 50,000 Horsepower Raw Water Supply System : The Southern Delivery System -- Fracture Behavior and Digital Image Correlation (DIC) Characterization of Multilayered Polymer Insulation Composite Coating Used in Subsea Pipelines.
Other Author Rahman, Shah, editor.
McPherson, David (Civil Engineer), editor.
American Society of Civil Engineers. Pipeline Division, sponsoring body.
American Society of Civil Engineers, issuing body.